Producción Científica Profesorado

Multicommutated Anodic Stripping Voltammetry at Tubular Bismuth Film Electrode for Lead Determination in Gunshot Residues



Rodríguez Ávila, José Antonio

2009

Rodriguez, J.A., Ibarra, I.S., Galan-Vidal, C.A., Vega, M., Barrado, E., Multicommutated anodic stripping voltammetry at tubular bismuth film electrode for lead determination in gunshot residues, Electroanalysis, 2009, Vol. 21, p.452-458, ISSN 1040-0397


Abstract


This work describes the construction of a miniaturized flow-through electrochemical cell and its application to the determination of lead in gunshot residues (GSR) by differential-pulse anodic stripping voltammetry at bismuth films co-deposited on-line on a tubular carbon paste electrode. The developed detector was coupled to a multicommutated flow system which was designed to allow medium exchange prior to the stripping step thus reducing interferences from the analytical matrix, and to implement the standard additions method in an automatic way, using only one standard solution. For a deposition time of 60?s at ?1.5 V at a flow rate of 0.5?mL min?1 without oxygen removal, the detection limit of the method was 0.2?mg L?1. Under these conditions the linear dynamic range was 0.310.0?mg L?1 with a sampling rate of 15.0?samples h?1. Repeatability of lead concentration was 3% (n=3). The method was applied to the analysis of lead in GSR on hands of shooters and concentrations up to 16.5??g and 6.7??g were found in palms and backs, respectively. No statistically significant differences between the results obtained by the proposed and the comparative method (F-AAS) were found, at a 95% confidence level.



Producto de Investigación




Artículos relacionados

Mercury Ions Removal from Aqueous Solution Using an Activated Composite Membrane

Metal content evaluation and its effect on the stability of anthocyanins

Development of a novel nitrate-selective composite sensor based on doped polypyrrole

Facilitated transport of Hg(II) through novel activated composite membranes

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Determination of oxytetracycline in milk samples by polymer inclusion membrane separation coupled to...

Sequential Injection Spectrophotometric Determination of Diclofenac in Urine and Pharmaceutical Form...

Influence of the Cation Nature of the Sulphate Salt on the Electrochemical Synthesis of Sulfate-Dope...

Simultaneous determination of tetracyclines in poultry muscle by capillary zone electrophoresis

Nucleation and Growth Kinetics of Electrodeposited Sulfate-Doped Polypyrrole: Determination of the D...