Producción Científica Profesorado

Determination of glucose by flow injection analysis with amperometric detection at Fe(III)-(tris(3,5-dimethyl-1-pyrazolyl)borate)2 modified electrodes



Rodríguez Ávila, José Antonio

2011

Hernandez, P., Rodriguez, J.A., Salazar, V., Álvarez-Romero, G.A., González-Montiel, S., Castrillejo Y. Determination of glucose by flow injection analysis with amperometric detection at Fe(III)-(tris(3,5-dimethyl-1-pyrazolyl)borate)2 modified electrodes, Journal of the Mexican Chemical Society, 2011, Vol. 55, p. 120-125, ISSN 1870-249X


Abstract


A modified screen printed electrode with [Fe(tris(3,5-dimethyl-1-pyrazolyl)borate)2] + [FeCl4]-, installed as part of a flow injection system, was used as an amperometric detector to determine hydrogen peroxide and glucose after on-line reaction with glucose oxidase. The influence of experimental variables on sensitivity, such asthe flow rate, injection volume and reaction coil length, was evaluatedusing a two-level factorial experimental design. Under optimal conditions, detection limits of 15 M and 0.5 mM for H2O2 and glucose, respectively, were obtained. A sampling rate of 60 determinations h-1 was achieved; the relative standard deviation of analytical measurements was <5.0%. The method was validated by comparing the obtained results with those provided by the enzymatic spectrophotometric method; no significant differences were observed (p < 0.05). Keywords: Glucose, Hydrogen peroxide, Flow injection system.



Producto de Investigación




Artículos relacionados

Design and Construction of Solid State Ag/AgCl Reference Electrodes Through Electrochemical Depositi...

Facilitated transport of Hg(II) through novel activated composite membranes

Electrochemical and AFM characterization of the electropolimerization of pyrrole over a graphiteepox...

Renewable stationary phase liquid magnetochromatography: determining aspartame and its hydrolysis pr...

Nucleation and Growth Kinetics of Electrodeposited Sulfate-Doped Polypyrrole: Determination of the D...

Sequential Injection Spectrophotometric Determination of Diclofenac in Urine and Pharmaceutical Form...

Potentiometric Behavior of Diverse Polypyrrolesulphate Films Electro Synthesized on Graphite Epoxy ...

Presence and antimicrobial resistance of Escherichia coli isolated from foodstuffs in Hidalgo State ...

Determination of non-steroidal anti-inflammatory drugs in wastewaters by magnetic matrix solid phase...

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...