Producción Científica Profesorado

Amperometric flow system for blood glucose determination using an immobilized enzyme magnetic reactor



Galan Vidal, Carlos Andres

2013

Hernandez, P; Rodriguez, JA; Galan, CA; Castrillejo, Y; Barrado, E., Amperometric flow system for blood glucose determination using an immobilized enzyme magnetic reactor BIOSENSORS & BIOELECTRONICS, Año 2013 Volume: 41 Pages: 244-248 DOI: 10.1016/j.bios.2012.08.033


Abstract


An amperometric flow system for glucose determination in blood serum samples after enzymatic reaction with glucose oxidase immobilized on magnetite covered with silica gel modified propylamine is described. The solid was magnetically retained on a mini-column and placed into the flow injection system preceding the amperometric detector using a modified screen printed electrode with [Fe(tris(3,5-dimetyl-1-pyrazolyl)borate)(2)](+) [FeCl4](-). The variables involved in the system such as flow rate, enzyme concentration, injection volume and reaction coil length were evaluated using a Taguchi parameter design. Under optimal conditions, the calibration curve of glucose sample was linear between 0.24 and 6.00 mM, and with a limit of detection of 0.08 mM. The repeatability for a 4.0 mM glucose solution was 1.0%. The method was validated by comparing the obtained results to those provided by the enzymatic spectrophotometric method; no significant differences were observed. (C) 2012 Elsevier B.V. All rights reserved.



Producto de Investigación




Artículos relacionados

THEORETICAL STUDY ON THE MODIFICATION OF ACTIVE SITES IN GOLD SURFACES MODELED AS FINITE CLUSTERS: I...

Influence of the Crystallinity of the Substrate on Kinetic Parameters of Zinc Electrodeposition Proc...

Theoretical and Experimental Study of Cobalt Nucleation and Growth onto Gold Substrate with Differen...

Nucleation and Growth Kinetics of Electrodeposited Sulfate-Doped Polypyrrole: Determination of the D...

Electrochemical kinetic study about cobalt electrodeposition onto GCE and HOPG substrates from sulfa...

A Voltammetric Study Of The Underpotential Deposition Of Cobalt Onto A Glassy Carbon Electrode

Kinetic study of the cobalt electrodeposition onto glassy carbon electrode from ammonium sulfate sol...

Mercury Ions Removal from Aqueous Solution Using an Activated Composite Membrane

Cobalt electrodeposition onto highly oriented pyrolytic graphite (HOPG) electrode from ammonium sulf...

Morphological and magnetic properties of cobalt nanoclusters electrodeposited onto HOPG