G.Y. Aguilar-Lira, G.A. Álvarez-Romero, A. Zamora-Suárez, M. Palomar-Pardavé, A. Rojas-Hernández, J.A. Rodríguez-Ávila, M.E. Páez-Hernández. New insights on diclofenac electrochemistry using graphite as working electrode. Journal of Electroanalytical Chemistry 794 (2017) 182-188. doi:10.1016/j.jelechem.2017.03.050


Abstract


This paper reports new investigation on the electrochemical behavior of diclofenac using a bare graphite electrode. The electrochemical oxidation of diclofenac was studied using cyclic voltammetry (CV), an anodic peak was found at 0.557 V as reported earlier by other authors, reversing the cycle results in a new cathodic peak at 0.272 V, which is proposed to be related with the reduction of 2-(2hydroxyprop-2-enyl) acetic acid. During the second cycle a new cathodic peak is observed at 0.333 V, associated to the oxidation of 2-(2hydroxyprop-2-enyl) acetic acid to 1-hydroxy-2-(hydroxyphenyl) ethanalate. Both electrochemical processes resulted to be adsorption-controlled, statistical fit of theoretical information with the experimental voltammograms, one electron transference is demonstrated which supports the proposed mechanism. From an analytical point of view, it was demonstrated that direct quantification of diclofenac using the anodic oxidation peak results less favorable when compared with an indirect quantification using the 2-(2hydroxyprop-2-enyl) acetic acid oxidation peak. The modified Simplex method was used to optimize differential pulse voltammetry parameters to achieve an exact and precise quantification of diclofenac in standard and real samples obtaining very competitive results compared with other more sophisticated working electrodes.



Producto de Investigación




Artículos relacionados

Development of a Polypyrrole Selective Membrane For The Potentiometric Quantification of Saccharinat...

Electrochemical and AFM characterization of the electropolimerization of pyrrole over a graphiteepox...

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...

High-performance liquid magneto-chromatography

Validation of a tubular bismuth film amperometric detector: Determination of diclofenac sodium by mu...

Chemical studies of anthocyanins: A review

Characterization of Main Anthocyanins Extracted from Pericarp Blue Corn by MALDI-ToF MS

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Presence and antimicrobial resistance of Escherichia coli isolated from foodstuffs in Hidalgo State ...

Estudio de las Interacciones Ácido Húmico-Metales Pesados y Determinación de sus Constantes de Estab...