Producción Científica Profesorado

Magnetic Solid-Phase Extraction Based on Poly 4-Vinyl Pyridine for HPLC-FLD Analysis of Naproxen in Urine Samples



Ibarra Ortega, Israel S.

2020

Escamilla-Lara, K.A., Heredia, A.C., Peña-Alvarez, A., Ibarra, I.S., Barrado, E., Rodriguez, J.A. Magnetic solid-phase extraction based on poly 4-vinyl pyridine for HPLC-FLD analysis of naproxen in urine samples. Molecules, 2020,25, 25122924. DOI: 10.3390/molecules25122924


Abstract


A magnetic solid phase extraction technique followed by liquid chromatography with a fluorescence detector for naproxen analysis in human urine samples was developed. The method includes the extraction of naproxen with a magnetic solid synthetized with magnetite and poly 4-vinylpriridine, followed by the magnetic separation of the solid phase and desorption of the analyte with methanol. Under optimal conditions, the linear range of the calibration curve was 0.05?0.60 ?g L?1, with a limit of detection of 0.02 ?g L?1. In all cases values of repeatability were lower than 5.0% with recoveries of 99.4 1.3%. Precision and accuracy values are adequate for naproxen (Npx) analysis in urine samples.



Producto de Investigación




Artículos relacionados

Construction and Evaluation of a Gold Tubular Electrode for Flow Analysis: Application to Speciation...

Presence and antimicrobial resistance of Escherichia coli isolated from foodstuffs in Hidalgo State ...

Electrochemical and AFM characterization of the electropolimerization of pyrrole over a graphiteepox...

Magnetic solids in analytical chemistry: A review

Influence of the Cation Nature of the Sulphate Salt on the Electrochemical Synthesis of Sulfate-Dope...

Development of a novel nitrate-selective composite sensor based on doped polypyrrole

Potentiometric behavior of graphite-epoxy electrochemical transducers towards anions, cations and pH...

Sequential Injection Spectrophotometric Determination of Diclofenac in Urine and Pharmaceutical Form...

Sequential Injection Spectrophotometric Determination of Diclofenac in Urine and Pharmaceutical Form...

Validation of a tubular bismuth film amperometric detector: Determination of diclofenac sodium by mu...