Producción Científica Profesorado

Micro flow injection analysis of leucomalachite green in fish muscle using modified henequen fibers as microfluidic channels



Rodríguez Ávila, José Antonio

2021

T. Alexandra Ferreira, Alfredo Guevara-Lara,M. Elena Paez-Hernandez, Alicia C. Mondragon and Jose A. Rodriguez. Micro flow injection analysis of leucomalachite green in fish muscle using modified henequen fibers as microfluidic channels. RSC Adv., 2021,11, 35375-35382 https://doi.org/10.1039/D1RA06301D


Abstract


In this work a simple and novel procedure for leucomalachite green determination based on micro flow injection analysis (?FIA) with amperometric detection is presented. The method involves the use of henequen modified fibers as microfluidic channels. The ?FIA system proposed offers a simple, rapid, and low-cost alternative for the determination. Capillary and gravitational forces across the modified henequen fibers control the flow rate, eliminating the need for external pumps. This technique requires low reagent consumption and allows portability for in situ measurements. The flow system is described, and the operational variables were studied and optimized using a Taguchi parameters design to increase analytical sensitivity. Under optimal conditions a limit of detection of 1.16 ?g kg?1 was achieved with adequate repeatability and reproducibility (expressed as %RSD <5.0%, n = 3, n = 9 respectively) in all cases. The effect of interfering species and the accuracy of the method were also investigated. The proposed methodology was validated and applied to determine LMG in tilapia muscle samples.



Producto de Investigación




Artículos relacionados

Presence and antimicrobial resistance of Escherichia coli isolated from foodstuffs in Hidalgo State ...

Mercury Ions Removal from Aqueous Solution Using an Activated Composite Membrane

Development of a novel composite sensor based on doped pyrrole selective to nitrate ions

Metal content evaluation and its effect on the stability of anthocyanins

Chemical studies of anthocyanins: A review

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...

Facilitated transport of Hg(II) through novel activated composite membranes

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...

Multicommutated Anodic Stripping Voltammetry at Tubular Bismuth Film Electrode for Lead Determinatio...